75
RG SERIES ENGINEERING GUIDE
Wiring Schematics
Aurora Base Control 208-230/60/1 PSC with GeoStart
P13
P4
SW1
P5
JW2
P9
ES
LS
LO
O/B
Y2
W
DH
P2
P8
P7
RS485 NET
RS485 NET
P6
RS485 EXP
P3
SW2
On
Reheat/Normal
L – Pulse/Continuous
CC – Dual/Single
Acc – Dip 2
Acc – Dip 1
RV – B/O
FP2 – 15°F/30°F
FP1 – 15°F/30°F
F1
P1
C
PWM
1
2
3
4
5
6
7
8
ALM
ALG
ACC COM
ACC NO
ACC NC
R
C
G
Y1
EH2CEH1
C
CO
C
R
A-
B+C
RA-B+
Off
Fault
R
Status
G
Confi
Y
DH W Y2 Y1 G O/B C R LO R F FG CC CCG
CC2
HI
CC2
LO
CC2
G
REVREV FP1 FP1 FP2 FP2 LPS LPS HPSHPS
urora Base Control
ABC)
K1
K2
K3
K4
K5
K6
N/
CFM
F
R
C
CCGY1
C
R
Transformer
Thermistor
Rela
Coil
Switch - Condensate Overflow
Switch - High pressure
Switch - Low pressure
Polarized connector
Factory Low Voltage Wiring
Factory Line Voltage Wiring
Field Low Volta
e Wirin
Field Line Volta
e Wirin
Optional Block
DC Voltage PCB Traces
Internal Junction
Quick Connect Terminal
Field Wirin
Lu
Ground
Relay Contacts – N.O., N.C.
Field Zone Sensor Wiring
Legend
L1
Capacitor
T
1
2
3
CC – Compressor Contactor
CO – Condensate Overflow Sensor
ES – Emergency Shutdown
HP – High Pressure Switch
LP – Low Pressure Switch
FD – Freeze Detection Sensor
F1 – Fuse
1 – Optional, factory installed unit mounted disconnect.
2 – Swap blue and red leads for 208V operation.
3 – Optional, factory installed internal isolation valve.
Notes:
Condensate
Brown (23)
Black/White
Green
Yellow Black/White
Yellow
Slow Flash
Fast Flash
Flash Code
Status LED
LED1, Green
Confi
uration LED
LED2, Yellow
Fault LED
LED3, Red
Status LED (LED1, Green)
Normal Mode
Control is Non-Functional
Test Mode
Lockout Active
Dehumidification Mode
Reserved
Reserved
Load Shed
ESD
1 second on and 1 second off
Random Start Delay
Fast Flash
OFF
ON
Slow Flash
Fast Flash
Flash Code 2
Flash Code 3
Flash Code 6
Flash Code 4
Flash Code 5
Aurora LED Flash Codes
100 milliseconds on and 100 milliseconds off
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Reserved
Flash Code 7
Configuration LED (LED2, Yellow)
Fault LED (LED3, Red)
Fast Flash
Fast Flash
No Software Overide Flash ECM Setting
DIP Switch Overide Slow Flash
Normal Mode
Input Fault Lockout
High Pressure Lockout
Low Pressure Lockout
Low Water Coil Limit Lockout - FP1
Low Air Coil Limit Lockout - FP2
Reserved
Condensate Overflow Lockout
Over/Under Voltage Shutdown
Reserved
Reserved
Air/Water Coil Limit Sensor Error
Flash Code 1
OFF
Flash Code 2
Flash Code 3
Flash Code 4
Flash Code 5
Flash Code 8
Flash Code 6
Flash Code 7
Flash Code 9
Flash Code 10
Flash Code 11
ECM Configure Mode Fast Flash
Reset Configure Mode Off
Fuse
SW1 – Push button
SW2 – DIP package 8 position
RB – Blower Relay
RV – Reversing Valve Coil
2
1
3
Isolation
Valve
Red
(51)
Green
50)
White
52)
Note 3
Note 3
Red
53
Li
ht Emittin
Diode - Green
G
Light Emitting Diode - Yellow
Y
Li
ht Emittin
Diode - Red
R
97P817-02 11/08/10
L1L2
CC
T1T2
H M L
P3
PSC
Blowe
Moto
Grn
WhtBrn
Cap
3 Airflow
Settin
s
Black
White
Black
Blue
230V
Black
Red
208V
Note 2
13
RB
Note 1
Black
95
Red
97
Disconnect
Neutral
Ground
L1 L1
L2 L2
L3 L3
Unit Power Suppl
208-230/60/1
G
Green
93
Compressor
Cap
C
R
S
Black
Ta n
Red
Blue
Soft Start
Run Windin
Active
Start Windin
Common Windin
Red
Pink
Pink
Blue
Black
Black
Blue
Accessory Relay
Cycle with Blower
Cycle with Compressor
Water Valve Slow Open
Outdoor Air Damper
SW2-4
SW2-5
On
On
Off
Off
On
Off
Off On
Operation
Event
Normal Mode
Test Mode
Random Start Delay
Compressor On Dela
Compressor Minimum On Time
Compressor Short Cycle Delay
Blower Off Delay
Fault Recognition Delay – High Pressure
Start-Up Bypass – Low Pressure
Fault Reco
nition Dela
– Low Pressure
Start-Up B
pass – Low Water/Air Coil Limit
Fault Reco
nition Dela
– Low Water/Air Coil Limit
Fault Reco
nition Dela
– Condensate Overflow
Thermostat Call Reco
nition Time
Auxiliary Heat Staging Delay
Emergency Heat Staging Delay
Less than 1 second
5 to 80 seconds 1 second
5 seconds < 1 second
30 seconds 2 seconds
Less than 1 second
2 minutes 5 seconds
4 minutes 15 seconds
2 minutes
2 minutes
30 seconds
30 seconds 30 seconds
30 seconds
30 seconds
30 seconds
30 seconds
30 seconds
2 seconds 2 seconds
5 minutes
2 minutes
20 seconds
7.5 seconds
urora Timing Events
Reheat Delay
30 seconds 30 seconds
Water Valve Slow Open Delay
90 seconds 90 seconds
24V
RB
CC
Resistor
White
12
Black
13
Violet
14
Black (15)
Oran
e
01
Oran
e
02
RV
HPLP
T
FD
RV
Blue
07
Blue
08
Black (09)
Black (10)
Yellow
Yellow
LED4
LED5
G
G