| Port Settings
– 46 –
N
OTE
:
Avoid using flow control on a port connected to a hub unless it is
actually required to solve a problem. Otherwise back pressure jamming
signals may degrade overall performance for the segment attached to the
hub.
Current Port Status
Port – The number of the port or trunk interface.
State – Indicates if the port is enabled or disabled.
Speed/Duplex – Displays the following:
Config – The configured speed/duplex mode of the port.
Actual – Indicates the link status of the port. When a link is up,
indicates the operating speed and duplex mode.
Flow Control – Displays the following:
Config – The configured flow control mode of the port.
Actual – Indicates the link status of the port. When a link is up,
indicates the operating flow control mode.
WEB INTERFACE
To configure port connection settings in the web interface:
1. Click System, Port Setting.
2. Select one or more ports or trunks to configure.
3. Make any required changes to the connection settings.
4. Click Apply.