Select “CPB-AES-128” if you want to use this protocol to maintain
privacy on your network.
11. Enter a password in the “Priv Password” field.
N
OTE
:
The Authorization Protocol and Password and Privacy Protocol and
Password fields are enabled only if you select the SNMP V3 field.
12. Enter the name of the user in the “Username” field.
13. Enter a password for accessing an SNMP agent in read-only mode in
the “Read Community” field.
14. Enter the name of the SNMP write community in the “Write
Community” field.
N
OTE
:
The Read Community and Write Community fields are available only
if you select the SNMP V1/V2C option.
15. In the “Common Settings” section, the following options are available:
Port number - Enter a UDP port number in this field.
Max Retries - Enter the maximum number of retries for each
SNMP attempt that does not receive a response. The retry value
allows the application to continue operation during network
problems.
Timeout (seconds) - Enter the time in seconds. Set the SNMP
timeout value to twice the average end-to-end delay in your
network. During high traffic periods, you might experience
timeouts. Increase the timeout interval if you consistently
experience timeouts.
16. Select Save.
MODIFY SNMP PROFILE
To modify an SNMP Profile, perform the following steps:
1. From the Preferences - SNMP Profiles dialog box, click the “Modify”
button to modify details of the SNMP profile. You will see the SNMP
Profile dialog box.
2. Make the required changes and click OK.